Need Real Answers for your Specific Use Case? Talk to our Engineers
BST 13C: Screw-Mount Crash Accelerometer
Bay SensorTec GmbH
Generating/Updating Your Configure-to-Order tool...
1
The W5 Engineering Advantage
20+ Years in Testing
All Across North America
Trusted by Industry Leaders
24-Hour Engineering Replies
Secure Order Processing
ISO-Level Quality Assurance
The model BST 13C is a uniaxial accelerometer based on piezo resistive technology. This accelerometer is designed for impact testing. The fully Wheatstone-Bridge (4 wire system) configuration helps to connect the sensor on all data acquisition systems. The very light weight and small size of the sensor makes it easy to mount it on difficult positions at the car for a crash test or for shock test application.
Due to the anodized aluminium housing and the position of the seismic mass it is possible to use it for crash test. With a 6 m, very rugged, shielded and flexible 4-wire cable all common connectors are mountable. As an option, we supply the sensor with a Dallas ID and a Shunt resistor in the connector. A calibration for the sensor is obligatory.
Features
Meets SAE J211 spec.
High Shock
Small size
Aluminium Housing, anodized
DC Response
Calibration
Application
Some of the use cases for the BST 13C Uniaxial include:
At a Glance
Best for: Uniaxial damped crash and shock tests that need a firm two-screw mount
Range: 500, 1,000 or 2,000 g; to 3,000 Hz; 8,000 g shock limit
Size & mount: 0.92 × 0.68 × 0.32 in (23.4 × 17.2 × 8.2 mm), 0.32 oz (9 g), 2 × M2
Environment: IP64, −4 to 176 °F (−20 to 80 °C), damping ratio 0.7, SAE J211
Which BST 13C Uniaxial range do I need?
Parameter | 500 g | 1,000 g | 2,000 g |
|---|---|---|---|
Range | ±500 g | ±1,000 g | ±2,000 g |
Sensitivity (typ.) | 0.04 mV/g | 0.018 mV/g | 0.016 mV/g |
Frequency response | 2,000 Hz | 2,750 Hz | 3,000 Hz |
Resonance frequency | >13 kHz | >20 kHz | >23 kHz |
Shock limit | 6,000 g | 8,000 g | 8,000 g |
BST 13C Uniaxial FAQ
Three ranges: 500 g, 1,000 g, and 2,000 g.
3 to 10 VDC constant.
−4 °F to 176 °F (−20 °C to 80 °C).
Additional cable length, connector, Dallas ID, shunt resistor, and DAkkS DIN EN ISO/IEC 17025:2018 calibration.
BST 13C: Screw-Mount Crash Accelerometer
Bay SensorTec GmbH
Generating/Updating Your Configure-to-Order tool...
1