Optris CTratio 1M — Fiber-Optic Two-Color Ratio Pyrometer, 842 °F to 5,432 °F
What it is
The Optris CTratio 1M is a rugged fiber-optic two-color (ratio) pyrometer for non-contact temperature measurement from 842 °F to 5,432 °F (450 °C to 3,000 °C) across three models. It measures infrared radiation at two closely spaced wavelengths in the 0.8 to 1.1 µm range and evaluates the ratio between them, so readings stay reliable when emissivity is unknown or changes with temperature, when the target only partly fills the measuring spot, and when dust, smoke or steam attenuate the signal by up to 90%. A green laser shows the real spot size at any distance, the vario optics focus from 5.90 in (150 mm) to infinity with up to 100:1 optical resolution, and the electrically isolated sensing head and fiber work up to 599 °F (315 °C) without cooling.
At a Glance
Range: 842 °F to 5,432 °F (450 °C to 3,000 °C), 0.8 to 1.1 µm
Optics: 38:1 or 100:1, vario focus from 5.90 in (150 mm) to infinity
Speed: 1 ms to 10 s response, ±(0.5% of reading + 3.6 °F / 2 °C)
Build: Two-color fiber optic; head and fiber to 599 °F (315 °C)
Principle
Two-color
Ratio measurement keeps readings stable with changing emissivity and up to 90% signal attenuation.
Optics
Up to 100:1
Close-focus optics reach a 0.059 in (1.5 mm) spot at 5.90 in (150 mm).
Heat
599 °F head
The electrically isolated sensing head and fiber run to 315 °C without cooling.
What it is used for
Some of the use cases for the CTratio 1M include:
Metalworking: high-temperature processes where emissivity varies or viewing windows get dirty
Small or partly filled targets: such as metal rods or wires that don't fill the measuring spot
Semiconductor manufacturing: critical temperature control
Advanced materials: high-temperature processing
Wire arc additive manufacturing: infrared temperature control
Models
Choose the model whose range covers your process temperature. Full data, including spot sizes, is in the Specifications tab.
Model
Range, 1-channel mode
Range, 2-channel mode
Optical resolution
Min. fiber bending radius
1ML
842 °F to 2,552 °F (450 °C to 1,400 °C)
977 °F to 2,552 °F (525 °C to 1,400 °C)
38:1
3.15 in (80 mm)
1MH
1,202 °F to 3,632 °F (650 °C to 2,000 °C)
1,292 °F to 3,632 °F (700 °C to 2,000 °C)
100:1
1.14 in (29 mm)
1MH1
1,652 °F to 5,432 °F (900 °C to 3,000 °C)
1,832 °F to 5,432 °F (1,000 °C to 3,000 °C)
100:1
1.14 in (29 mm)
Key features
Two-color measurement: compares two closely spaced wavelengths, so emissivity or process changes affect both signals proportionally
Up to 90% attenuation: stays reliable through dust, smoke, steam or soiled viewing windows
Smart Ratio Mode (SRM): for demanding applications with adaptive slope requirements
Green laser sighting: the 520 nm laser dot equals the real measurement spot size at any distance, for best visibility on glowing objects
Vario optics: standard focus (SFV) from 11.81 in (300 mm) to infinity, or close focus (CFV) from 5.90 in to 13.77 in (150 mm to 350 mm)
Rugged head: electrically isolated sensing head and fiber for ambient temperatures up to 599 °F (315 °C) without cooling
Signal processing: 1-color / 2-color mode, attenuation monitoring and alarms, peak hold, valley hold, average and extended hold with threshold and hysteresis
Three programmable I/Os: alarm output, trigger input for signal output and peak hold, or analog input for external emissivity or slope adjustment
Software: optris CompactPlus Connect for Windows and the IRmobile Android app (Android 5.0 or later with USB-OTG)
Why engineers pick it
It measures through dirty optics. The ratio principle keeps readings reliable with up to 90% attenuation.
It handles changing emissivity. Both wavelength signals shift together, so the ratio stays true.
It sees small targets fast. Up to 100:1 optics and response times down to 1 ms.
The head survives the heat. Sensing head and fiber work at up to 599 °F (315 °C) without cooling.
CTratio 1M FAQ
They differ in spectral range and starting temperature. The CTratio 1M measures at 0.8 to 1.1 µm from 842 °F (450 °C); the CTratio 2M measures at 1.45 to 1.75 µm from 482 °F (250 °C). Both reach 5,432 °F (3,000 °C). The 1M electronics are rated to 140 °F (60 °C) ambient, the 2M electronics to 122 °F (50 °C).
Loosen the knurled screw on the sensing head, then turn the rotary button clockwise to focus farther or counterclockwise to focus closer. Tighten the knurled screw after alignment to secure the focus. The vario optics focus from 5.90 in (150 mm) to infinity.
The integrated laser sighting supports alignment and focusing. The size of the laser dot equals the real measurement spot size at any distance.
It is a class 2 laser per EN 60825-1:2014 (520 nm, less than 1 mW). Do not point it at the eyes of people or animals, do not stare into the beam, and avoid indirect exposure via reflective surfaces.
Yes, at ambient temperatures above 122 °F (50 °C). Use the laser only for sighting and positioning; permanent use can shorten laser diode life and heat the sensor.
Yes. The laser supply line must run through a switch or pushbutton installed no more than 6.6 ft (2 m) from the sensor. The laser can also be switched via the electronics box or software / app.
Both ends are labeled "Head" and "Box" and must be paired correctly. Plug in the cable, turn the fiber until it locks, and fix it with the knurled screw. Loosen the screw before removing the fiber, and never pull on the fiber.
3.15 in (80 mm) for the 1ML, and 1.14 in (29 mm) for the 1MH and 1MH1.
The device must be sent in if the fiber or sensing head is defective; recalibration is necessary.
Up to two spare fibers of the same length, including the optical sensing head, can be ordered together with the main unit. They are adjusted together with the CTratio, so spare fibers cannot be ordered later.
No. Do not connect a supply voltage to the analog outputs, as this destroys them. For a 2-wire sensor, see the Optris CSmicro series.
No. The built-in USB socket is for setup and later setting changes; repeated plugging can damage it. For continuous use, use the optional USB interface ACCTMIAC. A USB-powered unit works only in digital communication mode.
Don't move the head cable during measurement, use shielded cables only and ground the sensor shield. Avoid ground loops; it may be necessary to interrupt the ground connection inside the electronics box by moving the internal jumper (see the manual).
Yes. Run a separate instance of CompactPlus Connect for each pyrometer and connect them via USB, or on RS485 using the RS485-USB adapter.
Configuring and scaling
Select the options on this page and add to cart, or contact W5 for a quote on custom configurations. Ask W5 about isolated 16-bit analog outputs, relay outputs, RS232, RS485, Ethernet or Modbus RTU interfaces, the ACCTMIAC interface for permanent USB use, and up to two spare fibers with sensing head, which must be ordered together with the main unit.
Scope of supply
CTratio, mounting nut, mounting bracket, USB-C cable (incl. adapter for USB-A) and CTratio manual.
Get the CTratio 1M specified and supplied
W5 Engineering supplies Optris infrared temperature measurement products. We match the CTratio 1M model, optics and fiber length to your process temperature, target size and distance. Contact us with your process temperature and measurement distance and we will return a configuration recommendation and quote.