What it is
A programmable AC+DC power source for system integration or desktop use, delivering rated power at both its AC and DC outputs, in 500 VA and 1,000 VA versions, benchtop or 3U half-rack.
User Manual (e-book version)
Output reaches 350 Vrms AC or ±500 Vdc at 40 … 999.9 Hz. Ten output modes, sequence and simulate modes, arbitrary waveforms, and 100th-order harmonic measurement are built in.
- Four models: ASR-2050 and ASR-2100 (benchtop), ASR-2050R and ASR-2100R (3U, 1/2 rack)
- Rated power at AC and DC: 500 VA / 500 W or 1,000 VA / 1,000 W
- Output: 0 … 350 Vrms AC, −500 … +500 Vdc; 40 … 999.9 Hz (AC+DC mode from 1 Hz)
- Ten output modes: AC-INT, DC-INT, AC+DC-INT, AC-EXT, AC+DC-EXT, AC-ADD, AC+DC-ADD, AC-SYNC, AC+DC-SYNC, AC-VCA
- Low distortion: THD ≤0.2% at 50/60 Hz
- Measurements: Vrms, Vavg, Vpeak, Irms, Iavg, Ipeak, IpkH, P, S, Q, PF, CF, and 100th-order voltage and current harmonics
- Sequence, simulate, and arbitrary waveform functions (16 nonvolatile waveforms)
- Remote sense, customized output on/off phase angle, and slew rate (time or slope) modes
- Interfaces: USB, LAN, external I/O standard; RS-232C and GPIB optional
What it is used for
Some of the use cases for the ASR-2000 Series include:
- Electronic component development — abnormal power line conditions such as falls, surges, and sags
- Automotive electrical devices — momentary drop in supply voltage, reset behavior, starting profile waveforms
- Home appliance testing — power outage, voltage rise, voltage fall, and frequency variation simulation
- Inrush current measurement — T, Ipk Hold captures surge current at DUT power-on
- Automated test systems — 3U half-rack R models compatible with ATS assembly, etc.
What does the ASR-2000 Series do?
The ASR-2000 series, an AC+DC power source aiming for system integration or desktop applications, provides both rated power output for AC output and rated power output for DC output. Ten ASR-2000 output modes are available: 1) AC power output mode (AC-INT), 2) DC power output mode (DC-INT), 3) AC/DC power output mode (AC+DC-INT), 4) external AC signal source mode (AC-EXT), 5) external AC/DC signal source mode (AC+DC-EXT), 6) external AC signal superimposition mode (AC-ADD), 7) external AC/DC signal superimposition mode (AC+DC-ADD), 8) external AC signal synchronization mode (AC-SYNC), 9) external AC/DC signal synchronization mode (AC+DC-SYNC), and 10) external DC voltage control of AC output mode (AC-VCA).
The ASR-2000 series provides waveform output capabilities that meet the test requirements of electronic component development, automotive electrical devices, and home appliances: 1) Sequence mode generates waveform falls, surges, sags, changes, and other abnormal power line conditions; 2) the arbitrary waveform function allows users to store and upload user-defined waveforms; and 3) Simulate mode simulates power outage, voltage rise, voltage fall, and frequency variations. While the ASR-2000 series outputs, it can also measure Vrms, Vavg, Vpeak, Irms, Iavg, Ipeak, IpkH, P, S, Q, PF, CF, and 100th-order voltage and current harmonics. In addition, the remote sense function ensures accurate voltage output. The customized phase angle for output on/off function sets the starting and ending angle of the voltage output according to the test requirements. V-Limit, Ipeak-Limit, F-Limit, OVP, OCP, and OPP settings protect the DUT during the measurement process. Besides OTP, OCP, and OPP protection, the ASR-2000 series also incorporates fan fail and AC fail alarm functions.
The ASR-2050 and ASR-2100 front panel provides a universal or European socket for plug-and-use operation, while the ASR-2050R and ASR-2100R are 3U high and 1/2 rack wide for ATS assembly.
Why engineers pick it
- Full rated power in DC, too. The ASR-2000 delivers its rated power at the DC output (500 W or 1,000 W, up to ±500 V), not only at AC.
- Abnormal power line conditions on demand. Ten sequence sets of 0 … 999 steps each, with step times of 0.0001 … 999.9999 s, create falls, surges, sags, and instantaneous power failures.
- Built-in power analysis. Voltage and current harmonics to the 100th order, crest factor, and peak hold measurements are made on the output itself.
- Controlled voltage rise. Slew rate "Time" mode reaches 10 … 90% of the set voltage within 100 µs; "Slope" mode rises at a fixed 1.5 V/µs.
Which ASR-2000 model do I need?
| Model | Power rating | Max. output current (100 V / 200 V range) | Max. output voltage | Form factor |
| ASR-2050 | 500 VA | 5 A / 2.5 A | 350 Vrms / 500 Vdc | Benchtop, front-panel output socket |
| ASR-2100 | 1,000 VA | 10 A / 5 A | 350 Vrms / 500 Vdc | Benchtop, front-panel output socket |
| ASR-2050R | 500 VA | 5 A / 2.5 A | 350 Vrms / 500 Vdc | 3U, 1/2 rack |
| ASR-2100R | 1,000 VA | 10 A / 5 A | 350 Vrms / 500 Vdc | 3U, 1/2 rack |
For three-phase output (1P2W, 1P3W, 3P4W), three identical ASR-2000 models can be combined with the ASR-002 external three-phase control unit.
When is the ASR-2000 the wrong choice?
- Full features in three-phase mode. With the ASR-002 three-phase control unit, DC output, harmonic analysis, remote sensing, arbitrary waveforms, sequence and simulation, external control I/O, and memory are not available, and communication is USB only.
- Power above 1 kVA. The series tops out at 1,000 VA / 1,000 W.
- Large cable drops. Remote sense compensates up to 5% of the output voltage.
- Hot environments. Operating temperature is 32 … 104 °F (0 … 40 °C).