What it is
A three-in-one multi-channel electrical safety tester: AC withstanding voltage to 5 kV, DC withstanding voltage to 6 kV, and insulation resistance to 1,000 V, with a built-in 8-channel scanner.
User Manual (e-book version)
Built on a 150 VA AC output platform and designed to IEC 61010-2-034, the GPT-9500 suits routine safety tests of general electronic components and winding components. All eight scanning channels sit on the rear panel.
- 3-in-1 tester: AC withstanding (5 kV), DC withstanding (6 kV), insulation resistance (1 kV)
- 150 VA AC test capacity (5 kV/30 mA)
- Built-in 8-channel scanner, with all channel outputs on the rear panel
- Insulation resistance measurement up to 10 GΩ
- Open/short check (OSC) and ARC detection
- Statistics (counter) function: total tests and number of NO-GOs
- 4.3-inch color TFT LCD (480 × 272), with tabular AUTO mode results
- Test parameter export/import through USB host
- Multi-language: English, Traditional Chinese, Simplified Chinese
- Interfaces: RS-232C, USB host/device, Signal I/O
What it is used for
Some of the use cases for the GPT-9500 Series include:
- Routine safety tests of general electronic components
- Winding components such as transformers — mutual testing of multiple points on a single component (GPT-9513)
- Passive components — high-voltage testing between two points (GPT-9503)
- Production lines — copying test settings across testers by USB flash drive, etc.
What does the GPT-9500 Series do?
The GPT-9500 series is a three-in-one multi-channel hipot tester, providing AC withstanding voltage (5 kV max.), DC withstanding voltage (6 kV max.), and insulation resistance (1,000 V max.). The design of the series conforms to the latest IEC 61010-2-034 standard requirements and it is built on the output platform of AC 150 VA.
This series has 2 models, and each model has a built-in 8-channel scanner. The series meets IEC, EN, UL, CSA, GB, JIS, and other safety regulations. It aims at the needs of the main test items of general electronic components or winding components during routine tests.
The status of the 8 channels of the GPT-9513 can be set to H, L, or X according to the test requirements, which is especially suitable for winding components such as transformers, to perform mutual testing of multiple points on a single component. The status of the 8 channels of the GPT-9503 only provides the setting of H or X, which is more suitable for general components such as passive components for high-voltage testing between two points.
The 4.3-inch color LCD (480 × 272) gives complete measurement information and an easy interface. AUTO test supports tabular display, so all test results are visible without switching screens. Scanning channels are on the rear panel, which looks cleaner when rack mounted and helps prevent accidental contact during output. Disconnection detection on each channel avoids misjudged tests from a broken wire.
Extend Your Tests
- Meets IEC 61010-2-034 design requirements
- Built-in 8-channel scanner
- Test parameter export / import through USB host
- Statistic (counter) function
Why engineers pick it
- Eight test points without an external scanner. The built-in 8-channel scanner tests multiple points of a component in one sequence, with H/L/X channel status on the GPT-9513.
- Designed to IEC 61010-2-034. GW Instek describes the GPT-9500 as the world's first multi-channel hipot tester to comply with IEC 61010-2-034, with double insulation for input and output voltages, a safe output and warning mechanism, and post-test discharge.
- Fast line setup. Setting parameters export and import by USB flash drive, so one configured tester can be copied to every tester on the production line.
- Safety built in. Zero start avoids instantaneous voltage on the DUT, and an interlock lets you connect external protection devices.
Which GPT-9500 model do I need?
| Model | Channels | Channel status | Best for |
| GPT-9513 | 8 | H, L, or X | Winding components such as transformers; mutual testing of multiple points |
| GPT-9503 | 8 | H or X | General components such as passive components; high-voltage testing between two points |
H = high voltage, L = low (return), X = not used. Both models provide AC withstanding, DC withstanding, insulation resistance, and continuity testing.
When is the GPT-9500 the wrong choice?
- AC loads above 150 VA. Maximum rated AC load is 150 VA (5 kV/30 mA); DC is 50 W (5 kV/10 mA).
- AC test voltages above 5 kV. AC withstanding tops out at 5.000 kV and DC at 6.000 kV.
- Insulation resistance above 10 GΩ. IR measurement covers 0.1 MΩ to 10 GΩ, and above 2 GΩ requires a test voltage of 500 V or more.
- Ground bond testing. The GPT-9500 provides continuity testing at 100 mA DC, not a ground bond test at high current.
Included Accessories
- Power cord × 1
- Test lead GHT-115 × 1, GHT-116B × 1, GHT-116R × 8