Main Image
Main Image
Talk to our Engineers

Need Real Answers for your Specific Use Case? Talk to our Engineers

No sales scripts. Just technical feasibility:

Call us at 1-866-400-1300

or

E-mail

GW Instek — PEL-3000A/3000AH Series

Instek America

Generating/Updating Your Configure-to-Order tool...

See product documents

Accessories

1

The W5 Engineering Advantage

Icon for award

20+ Years in Testing

Icon for users

All Across North America

Icon for trust

Trusted by Industry Leaders

Icon for clock

24-Hour Engineering Replies

Icon for users

Secure Order Processing

Icon for Award

ISO-Level Quality Assurance

Overview
Specifications
Resources

What it is

A single-channel programmable DC electronic load in 150 V (PEL-3000A) and 800 V (PEL-3000AH) families, rated 175 W to 2,100 W, reaching 9,450 W with boosters.

Current resolution reaches 0.01 mA and the current slew rate 16 A/µs on the PEL-3000A. Seven operating modes, three operating functions, and automated BATT, OCP, and OPP tests are built in.

  • PEL-3000A (150 V): PEL-3021A (175 W), PEL-3041A (350 W), PEL-3111A (1,050 W), PEL-3211A (2,100 W booster)
  • PEL-3000AH (800 V): PEL-3021AH (175 W), PEL-3041AH (350 W), PEL-3111AH (1,050 W), PEL-3211AH (2,100 W booster)
  • Seven operating modes: CC, CV, CR, CP, CC+CV, CR+CV, CP+CV
  • Static, Dynamic, and Sequence functions; Sequence divided into Fast Sequence and Normal Sequence
  • Parallel operation: up to 5 units of the same model, or one PEL-3111A/AH with up to four boosters for 9,450 W
  • Current slew rate: up to 16 A/µs (PEL-3000A), 0.84 A/µs (PEL-3000AH)
  • Soft Start, adjustable UVP, GO/NO GO voltage input monitoring, current monitoring, and timer function
  • BATT, OCP, and OPP test automation
  • Protection: OVP, OCP, OPP, OTP, UVP, RVP
  • Interfaces: USB, RS-232/RS-485, LAN standard; GPIB optional

What it is used for

Some of the use cases for the PEL-3000A/AH Series include:

  • Switching power supplies (SPS) — for commercial and industrial computers
  • DC/DC converters and high-voltage batteries — with the PEL-3000AH
  • Rechargeable batteries — for electrical tools, battery modules, and automobile batteries
  • HEV current consumption simulation — to verify automobile batteries
  • Battery bleeding characteristic tests, etc.

What does the PEL-3000A/AH Series do?

The PEL-3000A series, a single-channel programmable DC electronic load with 0.01 mA current resolution and 16 A/µs current slew rate, is ideal for testing SPS (switching power supplies) for commercial and industrial computers. For heavy-duty devices such as cloud ecosystems running 24-hour nonstop operations, a stable and high-power supply, ranging from 175 W to 1,050 W, is required to maintain the normal operation of servers, hubs, and data storage and internet communications equipment.

Owing to the increasing demand for data transmission and large-scale data storage in telecommunications systems, the infrastructure of internet communications is expanding rapidly. This has greatly boosted market demand for telecommunications equipment powered by power supplies of 2,000 W and above. The flexible power combination of the PEL-3000A meets the test requirements of present high-power power supplies.

The PEL-3000AH programmable DC electronic load inherits the functions and features of the PEL-3000A series, while providing three current ranges on all models and adding voltage monitor BNC terminals on the front panel. The PEL-3000AH series, a single-channel programmable DC electronic load with 800 V and 0.84 A/µs current slew rate, is ideal for testing high voltage devices such as EV and HEV in-vehicle chargers, DC/DC converters, and high-voltage batteries.

For battery testing applications, the series offers three stand-alone models (175 W, 350 W, and 1,050 W) and a booster. Connecting 2,100 W booster units to master units brings the maximum load capacity of the whole system to 9,450 W, so the series covers power testing requirements from low and medium power through to high-power supplies.

The series has seven operating modes and three operating functions. Four are basic operating modes (constant current, constant voltage, constant resistance, and constant power) and three are advanced modes (CC+CV, CR+CV, and CP+CV). Static, Dynamic, and Sequence functions apply a fixed load level, switch between two levels, or switch among more than two levels. Dynamic and Sequence help simulate genuine load changes; for example, the series can simulate HEV current consumption to confirm that an automobile battery can supply sufficient power on the road.

The Soft Start function sets the current rise time when the load is turned on, reducing abnormal voltage drop in the power supply under test. Adjustable UVP, GO/NO GO voltage input monitoring, current monitoring, and the timer function that controls load activation time can be combined for battery bleeding characteristic tests, avoiding battery damage during the bleeding operation.

Missing alt text

Why engineers pick it

  • Scales from 175 W to 9,450 W. Three stand-alone models cover low and medium power, and one PEL-3111A/AH with four boosters reaches 9,450 W on the same platform.
  • Simulates real load behavior. Dynamic and Sequence functions switch between or among load levels, with T1 and T2 from 0.025 ms to 60 s, to reproduce profiles such as HEV current consumption.
  • Protects the supply under test. Soft Start sets the current rise time at turn-on, which reduces abnormal voltage drop in the DUT.
  • Battery testing without damage. Adjustable UVP, GO/NO GO monitoring, current monitoring, and the timer combine for bleeding characteristic tests that stop before the battery is harmed.

Which PEL-3000A/AH model do I need?

ModelVoltageCurrentPowerFunctionSize
PEL-3021A150 V35 A175 WFull-function single unit; parallel with same model, 5 units max.Half rack
PEL-3041A150 V70 A350 WFull-function single unit; parallel with same model, 5 units max.Half rack
PEL-3111A150 V210 A1,050 WFull-function single unit; parallel with same model, 5 units max., or with up to four PEL-3211AFull rack
PEL-3211A150 V420 A2,100 WBooster for PEL-3111A only; no control panel, cannot be operated aloneFull rack
PEL-3021AH800 V8.75 A175 WFull-function single unit; parallel with same model, 5 units max.Half rack
PEL-3041AH800 V17.5 A350 WFull-function single unit; parallel with same model, 5 units max.Half rack
PEL-3111AH800 V52.5 A1,050 WFull-function single unit; parallel with same model, 5 units max., or with up to four PEL-3211AHFull rack
PEL-3211AH800 V105 A2,100 WBooster for PEL-3111AH only; no control panel, cannot be operated aloneFull rack

Choose the A family for DUTs up to 150 V and the AH family for up to 800 V. The AH models also provide three current ranges throughout and front-panel voltage monitor BNC terminals.

When is the PEL-3000A/AH the wrong choice?

  • A booster on its own. The PEL-3211A and PEL-3211AH have no control panel and only operate in parallel with a PEL-3111A or PEL-3111AH.
  • Full mode coverage on the boosters. CV, CP, slew rate, and metering specifications are not listed for the PEL-3211A; it runs CC, CR, and CP in dynamic mode as part of a master system.
  • Low voltage on the AH family. Minimum operating voltage is 5 V at full current on the 800 V models, against 1.5 V on the 150 V models.
  • Fast slew rate at 800 V. The AH family reaches 0.84 A/µs, against 16 A/µs on the PEL-3000A.

Ordering Information

Missing alt text

Features

Operating voltage (DC):0 V to 150 V(PEL-3000A)/ 0 V to 800 V(PEL-3000AH)

Operating Mode : CC / CV / CR / CP / CC+CV / CR+CV / CP+CV

Parallel Connection of Inputs for Higher Capacity (Max : 9,450 W)

Support of High Slew Rate:Max. 16 A/μs((PEL-3000A)/ 0.84 A/μs(PEL-3000AH)

Run Program Function(GO/NO GO Test)

Sequence Function for High Efficient Load Simulations

Dynamic(Switching) Function:0.0166 Hz to 20 kHz

Soft Start Function:Off / On (1 ms to 200 ms, Res:1 ms)

Adjustable OCP / OVP / OPP / UVP Setting

Short Circuit Function

Timer function : Elapsed Time of load on

PEL-3000A/AH Series FAQ

The PEL-3000A Series is rated to 150 V; the PEL-3000AH Series is rated to 800 V, provides three current ranges on all models, and adds front-panel voltage monitor BNC terminals.

One PEL-3111A or PEL-3111AH with four PEL-3211A or PEL-3211AH boosters in parallel provides a maximum of 9,450 W.

No. It is a booster with no control panel and cannot be operated alone. It parallels with the PEL-3111A (or PEL-3111AH for the PEL-3211AH).

Up to 16 A/µs on the PEL-3000A Series and 0.84 A/µs on the PEL-3000AH Series.

USB, RS-232/RS-485, and LAN as standard, with GPIB optional (PEL-004).

90 … 132 Vac or 180 … 250 Vac, single phase, 47 … 63 Hz.