The PS-C is a miniature pressure sensor with a strain-gage bridge inside. The cable direction is parallel to the sensor surface.
The Kyowa PS-C is an ultra-thin, compact strain gage pressure sensor with a horizontal cable, for measuring point pressure distribution with many sensors. It covers rated capacities from 7.25 psi to 1,015 psi (50 kPa to 7 MPa) in a 0.236 in (6 mm) diameter body as thin as 0.024 in (0.6 mm), and installs with adhesive.
Ultra-thin: 0.024 in (0.6 mm) thick on PS-05KC to PS-10KC; 0.079 in (2 mm) on 2 to 7 MPa models
Compact: 0.236 in (6 mm) diameter, approx. 0.018 oz (0.5 g) excluding cable
Horizontal cable: cable exits parallel to the sensing surface
Strain gage bridge: 350 Ω input and output resistance
Natural frequency: 10 … 86 kHz (approx.), depending on capacity
Compensated temperature: 32 … 122 °F (0 … 50 °C)
Adhesive mounting: dedicated adhesive RC-19, supplied on request
Conforming to CE and RoHS
What it is used for
Some of the use cases for the PS-C include:
Pressure distribution measurement — many sensors bonded across a surface
Point pressure measurement — in spaces too thin for conventional pressure transducers
Oil pressure measurement — with the 2 to 7 MPa M2 models
Features
Ultra-thin
Installed by adhesives
Suitable for distributed pressure measurement by using multiple units
What does the PS-C measure?
The PS-C is a pressure sensor with a compact, thin structure that uses a strain gage as its sensing element, with a bridge formed inside the sensor. Pressure on the sensing surface produces an output proportional to excitation voltage. The sensors are installed with adhesive, which makes them suitable for measuring point pressure distribution using many units.
Why engineers pick it
Thin enough to bond on the surface. At 0.6 mm thick for capacities up to 1 MPa, the PS-C adds almost nothing to the surface it measures.
Wide capacity range in one family. Nine models cover 50 kPa to 7 MPa, all in the same 6 mm diameter.
Fast response on higher capacities. Natural frequency rises from about 10 kHz on the 50 kPa model to about 86 kHz on the 7 MPa model.
Many channels, small footprint. Approx. 0.5 g per sensor and adhesive mounting let many sensors cover one area.
Which PS-C model do I need?
Model
Rated capacity
Rated output
Temperature effect on zero
Natural frequency (approx.)
PS-05KC
7.25 psi (50 kPa)
0.25 mV/V or more
Within ±0.8% RO/°C
10 kHz
PS-1KC
14.5 psi (100 kPa)
0.5 mV/V or more
Within ±0.4% RO/°C
10 kHz
PS-2KC
29.0 psi (200 kPa)
0.85 mV/V ±30%
Within ±0.3% RO/°C
14 kHz
PS-5KC
72.5 psi (500 kPa)
1 mV/V ±20%
Within ±0.2% RO/°C
20 kHz
PS-10KC
145 psi (1 MPa)
1 mV/V ±20%
Within ±0.2% RO/°C
37 kHz
PS-20KC M2
290 psi (2 MPa)
1 mV/V ±20%
Within ±0.2% RO/°C
46 kHz
PS-30KC M2
435 psi (3 MPa)
1 mV/V ±20%
Within ±0.2% RO/°C
58 kHz
PS-50KC M2
725 psi (5 MPa)
1 mV/V ±20%
Within ±0.2% RO/°C
71 kHz
PS-70KC M2
1,015 psi (7 MPa)
1 mV/V ±20%
Within ±0.2% RO/°C
86 kHz
Rated output is sorted into classes divided by every 2% difference in output value. The rated output stated in the test data sheet is the center value of the class, so it may include a maximum error of ±1%.
Choose the lowest capacity that covers the expected peak pressure. The 2 to 7 MPa models are 2 mm thick instead of 0.6 mm.
When is the PS-C the wrong choice?
Corrosive liquids or gases. The liquid-contacting part is copper alloy. Do not use it with liquids or gases that could corrode this material.
Organic solvents. Epoxy adhesive is used to assemble the liquid-contacting part, so the sensor cannot measure organic solvents (toluene, ketone, etc.).
Liquids other than oil on the high capacities. Only oil may be measured with the PS-20KC M2 to PS-70KC M2.
Rough handling of the leads. The cables are direct, discrete wires (0.1 mm diameter). Handle these thin, fragile wires with care, especially at the base.
Temperatures outside −4 to 158 °F (−20 to 70 °C). Compensation covers 32 to 122 °F (0 to 50 °C).
PS-C FAQ
7.25 to 1,015 psi (50 kPa to 7 MPa), across nine models.
0.6 mm (0.024 in) on PS-05KC to PS-10KC, and 2 mm (0.079 in) on the 2 to 7 MPa models. Diameter is 6 mm (0.236 in).
With adhesive. The dedicated adhesive RC-19 is available on request when ordering the transducer.
The liquid-contacting part is copper alloy, assembled with epoxy adhesive. Avoid liquids or gases that corrode copper alloy and organic solvents such as toluene or ketone. The PS-20KC M2 to PS-70KC M2 may measure oil only.
1 to 2 V AC or DC recommended; 3 V AC or DC is the safe maximum.
Configure and order the PS-C
Choose the PS-C capacity your measurement needs, add the RC-19 adhesive, and order directly on this page. For questions, contact us.