W5-HPMT-OCP ELR-HS Series (30 kW – 2 MW+)

Elektro-Automatik (Tektronix)

Select a Model:

Type :

W5-HPMT-OCP: High-Power Regenerative DC Load Systems

Voltage Range (Vdc) :

0-80V

Current Range (Adc) :

0-1875A

Power :

150KW

Size :

24U

Outputs :

Single. Optional Multi-Channel

AC Input Voltage :

380-480V 3Φ AC

Display :

Yes

Waveform Generator :

Yes

Built-In Interfaces :

USB, Ethernet, Analog, Master-Auxilliary Bus

Safety :

PS Level, UL AC Circuit Protection, E-Stop

1

The W5 Engineering Advantage

Icon for award

20+ Years in Testing

Icon for users

All Across North America

Icon for trust

Trusted by Industry Leaders

Icon for clock

24-Hour Engineering Replies

Icon for users

Secure Order Processing

Icon for Award

ISO-Level Quality Assurance

High Speed Regenerative DC Load Systems for OCP ORv3 Power Shelves and 48 V Rack Architectures

Built to emulate real hyperscale power behavior, not just static load.

  • Up to 6 A/µs current slew rate for fast transient emulation in low-voltage, high-current applications
  • Up to 1000 A per 30 kW module for 48 V OCP power shelf and rack power validation
  • 30 kW in 4U, scalable to 300 kW per rack and 2 MW+ in integrated multi-rack systems
  • Regenerative operation returns energy to the grid and reduces thermal burden in high duty-cycle testing

W5 Engineering delivers modular, field-scalable high speed regenerative DC load systems purpose built for Open Compute Project (OCP) ORv3 power shelves, 48 V rack power architectures, AI and GPU power systems, server PSU validation, and advanced DC power development environments.

These systems are designed for the conditions that define modern hyperscale power validation: fast current transitions, high current density, repeatable transient behavior, and scalable rack-level power. For low-voltage, high-current configurations, W5 high speed platforms support targeted slew rates up to 6 A/µs, enabling accurate reproduction of dynamic load conditions seen in AI, accelerator, and server power environments.

Designed for OCP ORv3 and Diablo 0.5.2 Power Validation

OCP ORv3 power shelves operate in a low-voltage, high-current environment where dynamic behavior matters more than steady-state power alone. In these systems, validation is driven by how the shelf, PSU, bus structure, and protection scheme respond to fast load changes under real operating conditions.

For engineering teams working against OCP ORv3 and Diablo 0.5.2 design targets, dynamic load capability is central to evaluating:

  • 48 V power shelf stability during rapid current transitions
  • Voltage droop, overshoot, and recovery time under fast load steps
  • EDPP-driven transient behavior and current ramp performance
  • Current sharing across parallel power supplies and shelf architectures
  • Protection response, fault behavior, and redundancy validation

Rather than approximating these conditions with conventional DC loads optimized for static or slow-changing demand, W5 HPMT OCP platforms are engineered to reproduce the electrical behavior of real hyperscale workloads at both shelf and rack level.

High Speed Modular Architecture from 30 kW to 2 MW+

Each W5 HPMT OCP system is built from 30 kW / 4U high speed regenerative DC load modules, integrated into complete rack-level platforms with unified control, protection, system monitoring, and energy recovery. This modular architecture supports a common technology foundation from benchtop and development environments through full rack and multi-rack test installations.

Typical system configurations include:

  • 30 kW in 4U for module-level and early-stage power development
  • 150 kW in 24U for shelf-level development and validation
  • 300 kW in 48U for rack-level power shelf and bus testing
  • Multi-rack systems above 2 MW for cabinet, infrastructure, and large-scale DC power validation

Because all systems share the same core architecture, protection framework, control layer, and regenerative topology, engineering teams can standardize on a common platform strategy across server PSU validation, OCP ORv3 power shelf test, 48 V rack bus evaluation, battery backup unit testing, and cabinet-level DC power development.

What Makes W5 High Speed Systems Different

The core differentiator is not simply power level. It is the combination of dynamic performance, current density, regenerative efficiency, and scalable system architecture in a platform designed specifically for modern power validation labs.

At the module level, W5 systems deliver:

  • Up to 1000 A per 30 kW module at 80 V for low-voltage, high-current applications
  • Targeted slew rates up to 6 A/µs for high speed current transitions in 48 V-class validation environments
  • Fast, repeatable transient behavior for realistic emulation of AI and GPU-driven load conditions
  • Regenerative operation that feeds energy back to the AC source rather than dissipating it as heat

At the system level, W5 platforms provide a practical path from development to deployment. A team can start with a single high speed shelf emulator or rack-level transient test platform and scale into larger validation systems without changing the underlying technology, control philosophy, or safety framework.

This is important for hyperscale labs because the validation problem is rarely isolated to one box. Power shelf behavior affects rack behavior. Rack behavior affects upstream DC infrastructure. Test platforms need to scale the same way the system under test scales.

Built for Real Engineering Workflows

W5 HPMT OCP systems are not positioned as generic catalog DC loads. They are engineered as complete regenerative DC load platforms configured around the way modern labs actually test: automated sequences, transient profiles, protection studies, current sharing analysis, power shelf characterization, and long-duration high power validation.

That matters because hyperscale power teams are not looking for a load bank with a communications port. They are building repeatable validation capability around specific electrical behaviors, power envelopes, and standards-driven test targets.

W5 systems support that need with:

  • Modular expansion from single-output development systems to integrated rack and multi-rack platforms
  • Rack-level scaling from 150 kW to 300 kW and beyond
  • Low-voltage, high-current capability aligned to OCP ORv3 shelf validation needs
  • High speed transient response for shelf, PSU, and distribution behavior analysis
  • A regenerative architecture that lowers operating cost in sustained high power testing

Why This Matters for Hyperscale Power Programs

Hyperscale power architectures are no longer defined by static power numbers alone. They are defined by how power behaves under load transitions, how quickly systems recover, how parallel supplies share current, how protection responds, and how rack-level power structures perform under realistic compute-driven demand.

That is where W5 HPMT OCP platforms differentiate: high speed regenerative operation, modular rack scaling, high current density, and up to 6 A/µs slew rate capability in low-voltage high-current configurations, all in a system architecture built for real power lab deployment.

For teams designing to OCP ORv3 and Diablo 0.5.2 requirements, this directly addresses the validation challenges that matter most: shelf stability under dynamic loading, voltage deviation during EDPP events, current sharing across parallel supplies, protection response, and recovery behavior under fast load steps.

Build a Test Platform That Matches OCP ORv3 and Diablo 0.5.2 Reality

W5 Engineering builds high speed regenerative DC load systems for the exact problems hyperscale power teams are trying to solve: fast 48 V shelf transients, EDPP-driven load steps, PSU and bus stability, protection and redundancy behavior, and scalable rack-to-megawatt test infrastructure.

From 30 kW development platforms to 300 kW rack systems and 2 MW+ laboratory installations, W5 helps power architects, validation teams, and advanced manufacturing groups create test capability that aligns with OCP power shelf development roadmaps and next-generation AI data center requirements.

If you are defining or validating OCP ORv3 power shelves, server PSUs, 48 V distribution, or high power DC infrastructure for hyperscale deployment, W5 Engineering can configure a regenerative DC load platform around your actual voltage window, current demand, slew rate target, rack power objective, automation environment, and protection test requirements.

Bring us your Diablo 0.5.2 targets, transient profile, rack power objective, protection test matrix, or OCP shelf validation requirements, and W5 Engineering will configure a high speed regenerative DC load system from 30 kW to 2 MW+ around the way your lab actually tests.